| MODEL 501A- UV Biometer
is the continuation of the line of Robertson-Berger Weatherproof meters, that have been
employed in the worldwide network for UV-B monitoring. The UV-Biometer has been designed
by D.Berger and M.Morys, based on the experience gained during the Robertson-Berger meter
design (Berger 1976) and of research focused on the temperature dependency and
stabilization of the Robertson-Berger UV-B sensor (Blumthaler, Ambach, Morys, Slomka
1989). |
 |
|
|
| Find out how to submit your ultraviolet data to the World
Ozone and Ultraviolet Radiation Data Centre |
|
|
Model 501-UV Detector- technical specifications
| Spectral response |
Figure 1 |
| Measurement range |
0...9.99 MED/HR |
| Resolution |
better than 0.01 MED/HR |
| Accuracy |
within +/- 5% for daily total |
| UV signal output |
compatible with Model 501 Recorder w/software V1.4A |
| Sensor temperature output |
as above |
| Operating environment |
outdoors |
| Operating ambient temperature |
-20...50°C |
| Storage temperature |
-40...70°C |
| Temperature sensor measurement range |
-50...100°C |
| Temperature stabilization of the filter max. temperature differential: |
60°C heating above ambient
25°C cooling below ambient |
| nominal sensor temperature |
25°C |
| stabilization accuracy |
±1°C, ±0.2°C stability |
| temperature settling time |
<5 minutes for 20°C change |
| Cable length |
50 ft. (15m) standard, 200ft max |
| Diameter of the detector |
6" (15 cm) |
| Height of the detector |
5" (13 cm) |
| Weight |
2 lb. ( 0.9kg) |
|
|
|
MODEL 501A-UV detector has an analog output allowing
connection to a data logger. (The 501-UV detector has a digital output)
All the specifications for the 501-UV apply to the 501A-UV with the following additions:
| UV signal output |
0...+2.5V, 0.250 V/(MED/HR), 0.5mA max |
| Sensor temperature output |
-2.5...+2.5V, 1V=25°C, 20mV/°C sensitivity,0.5 mA max |
| Power requirements |
5.5...25V/5mA max for signal circuitry 11...15V/1A max for temperature
stabilization |
| Temperature settling time |
<10 minutes for 20°C change |
|
|
 |
|
Fig.1 UV-Biometer Detector Models 501 UV and 501A-UV |
|
|
MODEL 501- UVA measures long
wavelength UV (320 to 400 nanometers).This band accounts for 90% or more of the total
irradiance shorter than the visible reaching Earth. The remainder of the UV irradiance is
in the UVB, which is shorter than 320 nm.
A high proportion of UVA radiation (UVAR) emanates from the sky, so
that the good cosine response of the meter is important.
UVAR is unaffected by ozone, therefore, the rapid changes in UVBR which
occur as the ozone effective thickness changes with sun angle do not occur with UVAR. This
difference in the time course of these two UVR regions is distinctive and important.
The meter output gives irradiance in terms of milliwatts per cm2.
Integrating the irradiance over a period of time gives the dose in terms of joules per cm2.
The meter can integrate in time periods between 1 minute and 1 hour.
UVA radiation fades dyes and paints, degrades plastics, and produces
various biological effects.
|
|
|
Model 501-UVA Detector- technical specifications
| Spectral response |
Figure 1 |
| Measurement range |
0-10mW/cm2 |
| Resolution |
better than 0.01mW/cm2 |
| Accuracy |
within +/- 5% for daily total |
| UVA signal output |
compatible with Model 501 Recorder w/software V1.4A |
| Sensor temperature output |
as above |
| Operating environment |
outdoors |
| Operating ambient temperature |
-20...50°C |
| Storage temperature |
-40...70°C |
| Temperature sensor measurement range |
-50...100°C |
| Temperature stabilization of the filter max. temperature differential: |
|
| heating above ambient |
60°C |
| cooling below ambient |
25°C |
| nominal sensor temperature |
25°C |
| stabilization accuracy |
±1°C, ±0.2°C stability |
| temperature settling time |
<5 minutes for 20°C change |
| Cable length |
50 ft. (15m) standard, 200ft max |
| Diameter of the detector |
6" (15 cm) |
| Height of the detector |
5" (13 cm) |
| Weight |
2 lb. ( 0.9kg) |
|
|
|
MODEL 501A-UVA detector has an analog output allowing
connection to a data logger. (The 501-UVA detector has a digital output)
All the specifications for the 501-UVA apply to the 501A-UVA with the following
additions:
| UV-A signal output |
0...+2.5V, 0.250 V/(mW/cm²), 0.5mA max |
| Sensor temperature output |
-2.5...+2.5V, 1V=25°C, 20mV/°C sensitivity,0.5 mA max |
| Power requirements |
5.5...25V/5mA max for signal circuitry 11...15V/1A max for temperature
stabilization |
| Temperature settling time |
<10 minutes for 20°C change |
|
|
|

|
|
Fig.1 UV-Biometer Detector Models 501 UVA and 501A-UVA |
|