MICROTOPS II is a 5 channel hand-held ozonometer for measuring total
ozone column easily, accurately and dependably. Direct solar ultraviolet radiation at 3
discrete wavelengths within the UV-B range is measured and stored. Optionally, the
MICROTOPS II can measure total water vapor (936 nm) and aerosol optical
thickness (AOT) at
1020 nanometers. MICROTOPS II features an accuracy comparable to much larger and more
expensive instruments. Optional GPS receiver facilitates field operation. This instrument is
also available in standard WMO or custom configuration for sunphotometry (5 channels
- see
Ordering).
View this page in Spanish.
|
 |
|
|
| For more information on the Garmin GPS please visit www.garmin.com/products/gps12/
|
|
| Find out how to submit your MICROTOPS II ozone data to
the World
Ozone and Ultraviolet Radiation Data Centre |
|
| Field
Carrying Case Now Available!!! |
| A
new carrying case for the MICROTOPS II has just arrived. It provides excellent protection and toting convenience,
perfect if you’re traveling by car, ship, plane, or you’re in the
field. Check out some of the
features below: |
 |
 |
Well
padded, durable construction |
 |
Adjustable
shoulder strap |
 |
Pouch
for notepad, pencils, etc. |
 |
Velcro
strap to attach fellow GPS carrying case |
 |
MICROTOPS
II is fully operable while inside case |
|
|
|
|
Applications
 | Weather stations |
 | Scientific and educational studies |
 | Pollution monitoring |
 | Health care |
 | Material testing |
 | Photobiology |
 | Environmental monitoring |
|
|
|
Features
 | High accuracy. The highest grade filters are embedded into a solid cast
aluminum housing which assures accurate, stable optical alignment. Low noise electronics
and a 20 bit A/D converter allow high linearity, resolution and dynamic range. |
 | Ease of use. No computer knowledge is necessary to make measurements.
Just aim the meter at the sun, aligning the image of the sun with the cross-hairs and push
the button. In few seconds the measurement will be completed and the result stored in
memory. |
 | Portability. A small hand-held device is all you need to perform
measurements. No additional computer is necessary. |
 | Instantaneous results. The ozone and total water vapor calculation
algorithms are programmed into the MICROTOPS II and the final results of all stored scans
can be conveniently viewed on the LCD. The raw data is also stored to allow retrospective
adjustments of algorithms. |
 | Non-volatile memory. The raw data collected by the MICROTOPS II, as
well as calculated results are stored in non-volatile memory. Each data point is annotated
with date, time, site coordinates, solar angle, altitude, pressure and temperature. |
 | Low cost. By implementing the latest technology, instrument cost has
been brought well below that of comparable ozonometers, without sacrificing accuracy or
features. |
 | Computer interface. Connection to a PC through a serial interface
(RS232) enables transfer of collected data. MICROTOPS
Organizer, a Windows-based software
automates data retrieval and archiving. |
|
|
Specifications
| Optical channels |
305.5 ±0.3 nm, 2.0 nm FWHM
312.5 ±0.3 nm, 2.0 nm FWHM
320.0 ±0.3 nm, 2.0 nm FWHM
936 ±1.5 nm, 10 nm FWHM (optional)
1020 ±1.5 nm, 10 nm FWHM (optional) |
| Stray light |
1E-9 for 305.5 nm filter
1E-8 for 312.5 nm filter
1E-8 for 320.0 nm filter
1E-6 for 936 nm filter
1E-6 for 1020 nm filter |
| Resolution |
0.0001uW/cm² on 305nm channel |
| Dynamic range |
>300,000 |
| Viewing angle |
2.5° |
| Precision |
1-2% |
| Nonlinearity |
max 0.002% FS |
| Operating environment |
0 to 50°C, no precipitation |
| Computer interface |
RS-232C |
| Power source |
4xAA Alkaline batteries |
| Weight |
21 oz (600 grams) |
| Size |
4"W x 8"H x 1.7"D (10x20x4.3 cm) |
|
|
|
Ordering
Standard
 | Microtops II with 305, 312, and 320 nm channels |
 | Barometric pressure sensor |
 | Hard-shell carrying case |
 | Serial port cable |
 | Instruction manual |
Optional
 | 936 and 1020 nm channels for water vapor measurements |
 | GPS receiver for automatic location setup |
 | Field carrying case |
 | MICROTOPS data organizer software for Windows |
 | Tripod adapter |
 | Custom filter configuration for sunphotometry. Typical wavelengths include: 340, 380,
440, 500, 675, 870, 936 and 1020 nm |
|
MICROTOPS II DATA FORMAT
(Some data columns omitted for clarity) |
S/N |
DATE |
TIME |
LAT. |
LONG. |
ALT. |
PRES. |
SZA |
S305 |
S312 |
S320 |
SIG940 |
SIG1020 |
OZ305_312 |
OZ312_320 |
OZONE |
WATER |
AOT1020 |
3103 |
11/25/96 |
15:06:00 |
40.1 |
-75.13 |
20 |
1018 |
65.4 |
1.82 |
27.9 |
55.01 |
58.95 |
132.36 |
216.5 |
241.8 |
243 |
1.04 |
0.086 |
3103 |
11/25/96 |
15:06:11 |
40.1 |
-75.13 |
20 |
1018 |
65.4 |
1.81 |
27.8 |
54.71 |
58.8 |
132.2 |
216.7 |
241.7 |
242.8 |
1.04 |
0.087 |
3103 |
11/25/96 |
15:06:23 |
40.1 |
-75.13 |
20 |
1018 |
65.4 |
1.8 |
27.91 |
54.77 |
58.82 |
131.32 |
217.7 |
241.4 |
242.5 |
1.03 |
0.089 |
3103 |
11/25/96 |
17:48:32 |
40.1 |
-75.13 |
20 |
1014 |
62.6 |
1.56 |
20.9 |
35.55 |
20.85 |
48.42 |
228.4 |
245.1 |
245.8 |
0.96 |
0.56 |
3103 |
11/25/96 |
17:48:43 |
40.1 |
-75.13 |
20 |
1014 |
62.6 |
1.39 |
19.13 |
32.52 |
18.49 |
43.01 |
230.5 |
244.9 |
245.5 |
0.94 |
0.614 |
3103 |
11/25/96 |
17:48:54 |
40.1 |
-75.13 |
20 |
1014 |
62.6 |
1.52 |
20.49 |
34.96 |
20.23 |
47.43 |
228.9 |
245.4 |
246.1 |
0.97 |
0.569 |
3103 |
11/25/96 |
17:49:07 |
40.1 |
-75.13 |
20 |
1014 |
62.6 |
1.43 |
19.59 |
33.58 |
19.08 |
45.04 |
229.9 |
246.1 |
246.8 |
0.97 |
0.593 |
|
|